TECHNOLOGY IN MOTION

Car Lifts

RISE

RISE car lifts for a change of level on a small footprint

Access to the basement – and not a trace of a ramp

An access ramp needs additional length alongside the driving lane for the gradient and transitions. On small plots and in projects with few parking spaces, this space requirement is out of all proportion to the number of parking spaces served, and the ramp permanently shapes the access and outdoor area.

RISE car lifts need only the footprint of one parking space for the route between the levels. The area a ramp would occupy remains available for living space, open space or additional parking spaces.

Discuss your project

What are Swiss-Park RISE car lifts?

Swiss-Park RISE car lifts transport vehicle and driver between the levels on a hydraulically moved platform. The driver drives onto the platform and stays in the vehicle. The travel button is held down throughout the entire journey – when it is released, the movement stops. The parking solution moves the platform and uses sensors on both sides to check that the vehicle is correctly positioned. Swiss-Park is a Lödige Industries company.

The platform travels in a shaft constructed by the client. There is no cabin with cabin doors; at the stops, garage doors or shaft protection close off the shaft. On RISE-R-5-P and RISE-R-C, the platform carries a cover, the roof. In the lowered position, it closes the shaft opening and can be given flooring that connects to the access or courtyard.

Compare versions

Benefits of RISE car lifts

RISE replaces the ramp on the footprint of one parking space. Stroke, platform size, load capacity and the design of the surface are matched to the project.

Access to the parking level without a ramp
Change of level on the footprint of one parking space
Driver stays in the vehicle during the journey
Versions for one storey and for height differences of up to 11.5 metres
Platform dimensions matched to the intended vehicles
Versions with roof blend into the courtyard or access

Our Swiss-Park RISE car lifts at a glance

The choice depends on the height difference to be overcome, whether the area above the shaft is to remain usable, the pit depth that is structurally possible and the weight of the intended vehicles. RISE-P and RISE-R-5-P are designed for a height difference of up to 3700 mm, RISE-R-C with a guided platform for up to 11500 mm. RISE-R-5-P and RISE-R-C have a roof that closes off the upper shaft opening.

RISE-P

Replaces the ramp for one storey

Max. lifting height: 3.7 m

Max. speed: 0.10 m/s

Pit depth: 550 to 650 mm

Driver on board – operated with dead-man control

Particularly suitable for up to 15 parking places

RISE-R-5-P

Roof becomes part of the courtyard

Max. lifting height: 3.7 m

Max. speed: 0.08 m/s

Pit depth: 570 to 620 mm

Driver on board – operated with dead-man control

Particularly suitable for up to 15 parking places

RISE-R-C

Large height differences – with roof

Max. lifting height: 11.5 m

Max. speed: 0.10 m/s

Pit depth: 1500 mm

Driver on board – operated with dead-man control

Particularly suitable for up to 15 parking places

RISE car lifts compared

The four tabs compare RISE-P, RISE-R-5-P and RISE-R-C using the figures that have to be coordinated with the building design at an early stage. Stroke, pit dimensions and load capacity determine which product is structurally possible; RISE-R-5-P and RISE-R-C come into consideration when the area above the system is to become part of the courtyard or access.

Use and comfort

How are RISE car lifts used?

With all three products, driver and vehicle are transported together. The journey is not automatic: the travel button must be held down throughout the entire movement.

 RISE-PRISE-R-5-PRISE-R-C
Roofnot applicableCloses the shaft opening in the lowered position and takes a project-specific flooring – the area above the system remains usable as part of the courtyard or access
Recommended project sizeup to 15 vehicles
Driver on boardYes
Automatic journeyNo
Operation during the journeyTravel button, held down continuously – dead-man control
Vehicle positioningPosition sensors on both sides, positioning aid and drive-through sensors
Edge monitoringup to 4 safety light curtains
Roof monitoringnot applicableSensor mounting columns at a distance of 10 to 15 cm from the roof
AccessControl elements with RFID
In the event of a faultEmergency battery, manual emergency lowering and GSM emergency call system
Group of usersDefined group of instructed users

When the travel button is released, the movement stops. The operating concept applies to all three products.

Level access and performance

Which height differences can be overcome?

What matters is the height difference between the entry level and the destination level. The speed alone does not determine the cycle, because entry, positioning and the opening of the doors also play a part.

 RISE-PRISE-R-5-PRISE-R-C
Type of constructionScissor lift tableScissor lift table with roofPlatform on lateral guides with roof
Stroke2700 to 3700 mm2700 to 3700 mm3000 to 11500 mm
Speed7 to 10 cm/s6 to 8 cm/s7 to 10 cm/s
Guides in the shaftnot applicableproject-specific
Connection to a garage doorSectional or roller door; dimensions and control to be coordinated with the door supplier, position relative to the parapet to be taken into account for all products
Permissible access slopeDescending slope up to 4 per cent, ascending slope up to 14 per cent

Version and vehicle accommodation

Which vehicles can the platform accommodate?

Platform length and width are determined according to the intended vehicles. Note the reference value for the load capacity: with RISE-R-5-P and RISE-R-C, the flooring on the roof is included; with RISE-P, it is not.

 RISE-PRISE-R-5-PRISE-R-C
Load capacity2500 kg, optionally 3500 kgup to 5000 kgup to 5000 kg
Reference value for load capacityVehicle weightVehicle and flooring on the roof, flooring up to 250 kg/m²
Platform length5050 to 5950 mm5310 to 6450 mm5310 to 5950 mm
Platform width or clear passagePlatform 2400 to 2900 mm, clear passage 2300 to 2800 mmPlatform 2450 to 2950 mm, clear passage 2200 to 2700 mmClear passage 2500 to 3000 mm
Clear passage heightproject-specific, at least 2500 mm1800 to 2200 mm1800 to 2200 mm
Parapet height1200 to 2100 mm
Upper shaft closureDoor or shaft protection provided on siteRoof with project-specific flooring, usable as a parking space in the lowered position under certain conditions
DriveHydraulic, with manual emergency lowering

If the roof is used as a parking space, the vehicle parked there must be removed before the system is operated.

Building and planning

Which structural requirements must be taken into account?

The shaft and pit, technical area, drainage and door connection are coordinated with the building design at an early stage. The pit dimensions follow from the selected platform size, the depth from the type of construction.

 RISE-PRISE-R-5-PRISE-R-C
Pit depth550 to 650 mm570 to 620 mm1500 mm
Pit length5100 to 6000 mm5360 to 6500 mm5360 to 6000 mm
Pit width2500 to 3000 mm2500 to 3000 mm3000 to 3500 mm
Tolerance of finished dimensions+3 / -0 cm
StructureFloor and walls below the entry level in concrete, at least C20/25; anchoring in the floor and side walls
Support force F1+35 kN+70 kN+70 kN, F2 -2 kN
DrainageCollecting sump or permanently installed pumpSurrounding drainage channel connected to the sewer system, waterproofing of shaft and roof by others
Technical areaLockable, ventilated room for hydraulic power unit and control cabinet, temperature below 50 °C; two empty conduits of at least 100 mm to the pit, maximum length 13 m
InstallationIndoorIndoor and outdoor installation
Operating range-10 °C to +40 °C; in the event of snowfall, the system must be cleared before operation
Sound insulationMeasures in accordance with DIN 4109 by others, sound insulation package as per quotation
Emergency call systemTelephone connection or LAN connection to the control cabinet by others, emergency call connection is mandatory

When is RISE the right solution?

RISE is relevant when a parking level is to be accessed and there is too little space for a ramp. The systems are designed for projects with up to 15 vehicles. Typical contexts are Private Homes & Villas and private garages, Residential Buildings with manageable traffic volumes, Office Buildings, and Hotels & Commercial Buildings. Because the driver travels along and holds the travel button down during the journey, operation requires a defined and trained group of users.

For the design, the shaft and pit, structure, waterproofing, drainage and technical area are coordinated with the building design at an early stage, and door dimensions and control with the door supplier. RISE-P is designed for indoor installation; if the system is to be located outdoors, RISE-R-5-P and RISE-R-C with a roof come into consideration.

Discuss your project

Applications

RISE is mainly used where a small number of parking spaces are to be served and the group of users is fixed. The tabs show what matters for each building type.

Private Homes & Villas and private garages

On small plots, RISE connects a lower-lying garage with the access without a ramp having to be built. RISE-P is designed for a height difference of one storey.

If the vehicle is to be located beneath an access or outdoor area, RISE-R-5-P and RISE-R-C come into consideration: their roof becomes part of this area and takes the intended flooring.

Residential Buildings

In residential buildings, RISE provides access to a parking level for which a ramp would take up too much plot or building area. The solution is suitable as long as the traffic volume remains manageable and the residents can be instructed as a fixed group of users.

Whether RISE-P, RISE-R-5-P or RISE-R-C is suitable depends on the height difference to the parking level and on whether the area above the shaft is to remain usable.

Office Buildings

In office buildings, RISE creates a compact connection to parking areas on another building level. A prerequisite is a predictable group of users who are familiar with operating the system during the journey.

Vehicle dimensions, access, stroke and technical area are coordinated together at an early stage so that the system fits into the floor plan.

Hotels & Commercial Buildings

In hotels and smaller commercial buildings, RISE provides access to parking spaces on another level without a ramp shaping the access. Operation with the driver on board requires journeys to be made by instructed persons, for example staff in valet operation.

For higher traffic volumes or changing users, the car lifts TRAFFICO, CARRICO and PEGASOS are also considered during planning.

Everything from a single source – from planning to modernisation

Lödige supports your project throughout its entire life cycle – from system-independent planning and implementation through to service and modernisation.

Planning and consultancy

The right parking solution for your project

Whether mechanical, semi-automated or fully automated parking system: what matters are the requirements of the project. Lödige advises independently of any particular system, also assesses existing solutions from other manufacturers and develops a suitable parking concept based on many years of experience and a wide range of technical options.

a man fixing a lift
Service and modernisation

Operating parking systems reliably over the long term

Regular maintenance, fast support in the event of a service call and targeted modernisation safeguard the availability, safety and value of the system. Lödige looks after its own systems as well as systems from other manufacturers and supports operators throughout the entire life cycle.

Which RISE solution suits your project?

Speak with our experts to define your optimal equipment + software setup.

Frequently asked questions about RISE

Yes. Driver and vehicle are transported together. The journey does not run automatically: the travel button must be held down throughout the entire movement, and the system stops when it is released. This dead-man control requires a defined group of instructed users. An emergency battery, manual emergency lowering and a GSM emergency call system are part of the equipment.

RISE-P and RISE-R-5-P connect the entry level with an adjacent level and reach a stroke of 2700 to 3700 mm. RISE-R-C reaches 3000 to 11500 mm and also overcomes height differences spanning several storey heights; here, lateral guides guide the platform.

The platform is designed for the intended vehicles. The platform length is up to 5950 mm, and up to 6450 mm with RISE-R-5-P. The load capacity is 2500 kg and optionally 3500 kg with RISE-P and up to 5000 kg with RISE-R-5-P and RISE-R-C. With RISE-R-5-P and RISE-R-C, this value is the total load of the vehicle and the flooring on the roof; the flooring is counted at up to 250 kg/m².

With RISE-R-5-P and RISE-R-C, a roof closes off the upper shaft opening, takes project-specific flooring and integrates the system into the access or outdoor area. In the lowered position, it can be used as a parking space under certain conditions; the vehicle parked there must be removed before operation. Both also include a surrounding drainage channel connected to the sewer system and sensor mounting columns for monitoring the roof. RISE-R-5-P is a scissor lift table for a stroke of up to 3700 mm, RISE-R-C a guided platform for up to 11500 mm.

A shaft spanning the entire height difference is required. A pit is added beneath the lower level, 550 to 650 mm deep with RISE-P, 570 to 620 mm with RISE-R-5-P and 1500 mm with RISE-R-C. Also required are a floor and walls below the entry level in concrete, at least C20/25, drainage via a collecting sump or a permanently installed pump – with RISE-R-5-P and RISE-R-C additionally via a surrounding drainage channel – and an accessible, ventilated area for the hydraulic power unit and control cabinet. Door dimensions and control are coordinated with the door supplier.

RISE-P is designed for indoor installation. RISE-R-5-P and RISE-R-C are also suitable for outdoor installation – the roof is then part of the access or outdoor area. The operating range is between -10 °C and +40 °C. In the event of snowfall, the system, including the sensor paths, must be cleared before operation; the waterproofing of the shaft and roof is provided by others.

Contact form
Downloads